System Components

INDUSTRONIC offers different modular system components for the connection of INDUSTRONIC intercom stations, speakers and other terminal devices as well as the possibility to integrate third-party systems.

The system components are designed for installation into industrial 19" cabinets.

PMOD 1 XCO 001

X-Controller Module

Features and Functions

  • Controller for Intercom, PA/GA and PA solutions with up to 400 terminal devices
  • Networking of up to 250 X-Controllers
  • Control of warning sequences
  • 4 Gigabit Ethernet interfaces for flexible network connection
  • 12 bidirectional potential-free control inputs and outputs
  • Power supply of the internal electronics via PoE (with redundancy) or separate DC supply
  • Integrated self-monitoring
  • Configuration via INDUSTRONIC management tools
ipwolke

PMOD 8 XDG 001

Digital Gateway Module

Features and Functions

  • Connection of up to 8 digital INDUSTRONIC terminal devices via 2-wire technology
  • 2 Ethernet interfaces for redundant network connection
  • Redundant connection of terminal devices to 2 different XDG modules possible
  • Integrated self-monitoring
  • Permanent automatic monitoring of all connected terminal devices, connection cables, and power supplies
  • Configuration via INTRON-X management tools
ipwolke

PMOD 24 XIO 001

I/O Module

Features and Functions

  • 24 bidirectional potential-free control inputs and outputs
  • 2 Ethernet interfaces for redundant network connection
  • Power supply of the internal electronics via PoE (with redundancy) or separate DC supply
  • Integrated self-monitoring
  • Configuration via INDUSTRONIC management tools
ipwolke

PMOD 6 XAL 001

Analog Line Module

Features and Functions

  • 6 analog audio interfaces with
  • 2 x 4-wire audio (full duplex)
  • 4 x 2-wire audio (half duplex)
  • 24 bidirectional potential-free control inputs and outputs
  • 2 Ethernet interfaces for redundant network connection
  • Power supply of the internal electronics via PoE (with redundancy) or separate DC supply
  • Integrated self-monitoring
  • Configuration via INDUSTRONIC management tools
ipwolke

PMOD 4 XBC 001

Beacon Control Module

Features and Functions

  • Control of up to 4 AC or DC flashing warning beacon circuits
  • Flashing warning beacons can be wired as line or loop
    • Xenon, LED, etc.
    • 115 / 230 V AC
    • 24 / 48 / 60 V DC
  • Continuous automatic line monitoring of the flashing warning beacons for cable break, short circuit and ground leakage (option)
  • 2 Ethernet interfaces for redundant network connection
  • Power supply of the internal electronics via PoE (with redundancy) or separate DC supply
  • Integrated self-monitoring
  • Configuration via INDUSTRONIC management tools
ipwolke

Exchange Control Board

1 DXC 04
Exchange Control Board with connection of up to 192 digital or analog intercom station Exchange Control Board with connection of up to 192 digital or analog intercom station
Exchange Control Board with connection of up to 192 digital or analog intercom station
Exchange Control Board with connection of up to 192 digital or analog intercom station

Features and Functions

  • Connection of up to 192 digital or analog intercom stations
  • Addressing of up to 65,000 stations, speaker circuits, etc.
  • Switching of up to 120 simultaneous communication links
  • Connection of IP-based intercom stations
  • IP-based system interconnection via integrated Ethernet interfaces
  • LEDs to indicate operation, data transmission and errors

Linecard for 12 Digital Intercom Stations

12 DDL 02
Linecard for 12 Digital Intercom Stations Linecard for 12 Digital Intercom Stations
Linecard for 12 Digital Intercom Stations
Linecard for 12 Digital Intercom Stations

Features and Functions

  • Management of up to 12 digital intercom stations
  • Permanent monitoring of the connected intercom stations and connection cables (interruptions, short circuits)
  • Green LED to indicate operation, red LED to indicate failures
  • One green LED per each intercom station to indicate incoming and outgoing AF signals
  • One red LED per each intercom station to indicate specific intercom station failures  

Linecard for 12 Analog Intercom Stations

12 DAL 03
Linecard for 12 Analog Intercom Stations

Features and Functions

  • Management of up to 12 analog intercom stations
  • Management of 48 line inputs / outputs
  • Protected line outputs against short circuits and overvoltage
  • Blinking LED indicates an outgoing AF signal
  • Shining LED indicates an AF source
  • Red LED indicates failures
  • Hot swapping of the linecard 

IP Interface for Analog Systems

NSG 001
IP Interface for Analog Systems with 3 potential-free inputs and outputs, expandable to up to27 potential-free in- and outputs

Features and Functions

  • Interface to analog systems, with galvanic isolation
  • 3 potential-free inputs and outputs
  • Expandable to up to 27 potential-free inputs and outputs
  • Alternative wiring: bidirectional inputs/outputs
  • 4-wire AF interface with adjustable AF level
  • Continuous monitoring of network interface
  • PoE and/or external power supply
  • Integrated web interface for setting and service functions