{"id":4775,"date":"2023-02-20T14:29:15","date_gmt":"2023-02-20T13:29:15","guid":{"rendered":"https:\/\/www.industronic.com\/blog\/?p=4775"},"modified":"2023-02-20T14:29:15","modified_gmt":"2023-02-20T13:29:15","slug":"xio-endless-application-possibilities-for-the-control-of-inputs-and-outputs","status":"publish","type":"post","link":"https:\/\/www.industronic.com\/blog\/xio-endless-application-possibilities-for-the-control-of-inputs-and-outputs\/","title":{"rendered":"XIO \u2013 Endless Application Possibilities for the Control of Inputs and Outputs"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">In our blog posts last year, we already introduced the INTRON-X modules <a rel=\"noreferrer noopener\" href=\"https:\/\/www.industronic.com\/blog\/x-controller-the-intelligent-processor-unit-of-the-new-intron-x-system\/\" data-type=\"URL\" data-id=\"https:\/\/www.industronic.com\/blog\/x-controller-the-intelligent-processor-unit-of-the-new-intron-x-system\/\" target=\"_blank\">XCO<\/a> and <a rel=\"noreferrer noopener\" href=\"https:\/\/www.industronic.com\/blog\/xdg-the-digital-gateway-module-for-the-connection-of-digital-terminal-devices\/\" target=\"_blank\">XDG<\/a>. Today we want to proceed with the <strong>XIO &#8211; our I\/O module<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>XIO<\/strong><strong> \u2013 <\/strong><strong>Our Module for Successful Input\/Output Control<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The XIO is used to read in inputs and switch outputs. One XIO module has 24 bidirectional potential-free control I\/Os.<br>As the control inputs and outputs are divided into separate groups of 12, it is possible to connect two systems at different voltage potential to one XIO module.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The module has also 2 Ethernet interfaces which allow for a redundant network access. If one network interface fails, data is transmitted via the second one. The XIO has an automatic integrated self-monitoring function. So inputs and outputs, connection cables, and power supplies can be permanently monitored.<br>Together with flexible redundancy concepts (A+B and Hot-Standby) the XIO ensures continuous operation and maximum system availability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Application Examples<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"432\" src=\"https:\/\/www.industronic.com\/blog\/wp-content\/uploads\/2023\/02\/Schaubild-XIO-1-1024x432.png\" alt=\"\" class=\"wp-image-4780\" srcset=\"https:\/\/www.industronic.com\/blog\/wp-content\/uploads\/2023\/02\/Schaubild-XIO-1-1024x432.png 1024w, https:\/\/www.industronic.com\/blog\/wp-content\/uploads\/2023\/02\/Schaubild-XIO-1-300x126.png 300w, https:\/\/www.industronic.com\/blog\/wp-content\/uploads\/2023\/02\/Schaubild-XIO-1-768x324.png 768w, https:\/\/www.industronic.com\/blog\/wp-content\/uploads\/2023\/02\/Schaubild-XIO-1.png 1198w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Connection to F&amp;G Systems<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The XIO module is mainly used for the connection to a Fire &amp; Gas system via contacts. This system controls a wide variety of warning sequences. It is possible to start the pre-programmed evacuation sequence manually or automatically.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Connection to Building Management Systems (BMS)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If no network-based interface such as ModbusTCP is available, analog connection via the XIO is a practical solution. PLC devices from building management systems, for example, can also be connected via I\/O and thus exchange bi-directional control signals. This enables fire doors to be closed or an emergency shutdown to be transmitted to a BMS via a control signal in the event of an active alarm. Situation-dependent announcements are automatically issued, e.g., to prevent panic and significantly speed up evacuation through targeted instructions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Monitoring Functions<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It is also possible to integrate other systems into the INTRON-X monitoring via the inputs of the XIO. For example, fault messages from emergency power supplies, access control or CCTV systems can be read in and immediately transmitted to a control station.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Another option is the use of manual call points that, depending on the requirement, trigger a direct action or start an alarm only after confirmation from a control station.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Decentralized Installation<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As the XIO communicates with the INTRON-X controller via Ethernet, there is also the option of a decentralized installation. It can be installed anywhere where network access is available.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In addition, a software logic module can be activated within the INTRON-X using the Config Manager X, via which all input signals can be evaluated and processed. This makes countless if-then scenarios possible.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Extend your possibilities! Feel free to contact us for further information.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The XIO is used to read in inputs and switch outputs. One XIO module has 24 bidirectional potential-free control I\/Os.<br \/>\nAs the control inputs and outputs are divided into separate groups of 12, it is possible to connect two systems at different voltage potential to one XIO module.<\/p>\n","protected":false},"author":12,"featured_media":4778,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5],"tags":[177,184],"class_list":["post-4775","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technology","tag-intron-x","tag-xio"],"_links":{"self":[{"href":"https:\/\/www.industronic.com\/blog\/wp-json\/wp\/v2\/posts\/4775","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.industronic.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.industronic.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.industronic.com\/blog\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/www.industronic.com\/blog\/wp-json\/wp\/v2\/comments?post=4775"}],"version-history":[{"count":4,"href":"https:\/\/www.industronic.com\/blog\/wp-json\/wp\/v2\/posts\/4775\/revisions"}],"predecessor-version":[{"id":4782,"href":"https:\/\/www.industronic.com\/blog\/wp-json\/wp\/v2\/posts\/4775\/revisions\/4782"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.industronic.com\/blog\/wp-json\/wp\/v2\/media\/4778"}],"wp:attachment":[{"href":"https:\/\/www.industronic.com\/blog\/wp-json\/wp\/v2\/media?parent=4775"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.industronic.com\/blog\/wp-json\/wp\/v2\/categories?post=4775"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.industronic.com\/blog\/wp-json\/wp\/v2\/tags?post=4775"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}